Bantamware★Purveyors of featherweight software★Est. 2026
◂ Back to the card
Standby app icon

★ Bout V · new · available now ★

Standby

Takes the hit so your machine doesn’t. A tray-sized watchdog for the UPS under your desk — no vendor driver, no background service, no account.

Official weigh-in — Standby v1.2.0
70 KBOn disk
1.8 MBMemory at rest
0Services
0Vendor drivers

★ Scouting report ★

What it does

It reads charge, runtime, load and mains voltage straight off the battery over the USB cable you already have plugged in. When the power goes and doesn’t come back, it shuts the machine down cleanly while there’s still battery left to do it in — and stands down by itself if the mains returns mid-count. Your UPS already speaks the standard HID power protocol, so there is no vendor driver, no background service, no Java runtime and no account; it reads the device Windows already found and leaves the inbox battery driver exactly where it sits.

70 KB · Saved by the bell
Standby v1.2.0 · 64-bit Windows · signed · managed updates

★ Open interface ★

Push the load anywhere

Since v1.2.0 Standby can report what the UPS is carrying to anything you run. This is the contract; Wattle’s /submeter is one implementation of it, not the definition.

Once a minute, while on mains with a UPS connected, Standby sends one bearer-authenticated JSON POST to <your endpoint>/submeter. Nothing is sent on battery — the shutdown path is never held up by the network, so treat silence during an outage as missing data, not zero. A 200 means stored; anything else is retried a minute later and logged once, and the token is never logged. Set it up from the tray menu: Push load…

{"id":"office-ups",     stable meter id you chose (letters, digits, . _ -)
 "watts":207,           load in watts
 "label":"Office UPS",  display name you chose
 "volts":121.4,         mains voltage at this outlet
 "load_pct":23,         UPS load as % of rated capacity
 "battery_pct":100,     battery charge %
 "runtime_min":23}      estimated minutes remaining — fields the UPS doesn’t report are omitted

For the receiver: watts is everything downstream of this UPS — a subset of any whole-house figure you already have, so subtract it from your baseline rather than adding it on top. Hold a reading forward for a bounded time (Wattle uses 15 minutes) and treat a longer gap as missing.

★ The numbers ★

Standby vs. the bundled UPS software

Standby against the suite that ships in the box.

Standby
Red corner
vs.
PowerChute
Blue corner
70 KB
Weight on disk
Tens of MBan installer, to read a battery gauge
1.8 MB
Memory at rest
Many times thatand a service keeping it company
None
Background service
Always runningso the tray icon isn’t lonely
None
Vendor driver
Its ownfor a device Windows already found
Copy and run
Getting started
Install, rebootbefore it will tell you the time left
One job
What it actually does
EverythingStandby does the part that saves your work
Your UPS has been able to say “four minutes left” this whole time. Standby is the part that listens.